Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Lifetime Online Technial Support |
| Warranty: | 1year |
Secured Trading Service
Diamond Member Since 2024
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Fast Delivery
Low MOQ
R&D Capabilities
The supplier has import and export rights
The supplier can deliver the goods within 15 days
The MOQ for the supplier's products is 1
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Sign In to see all verified strength labels (5)
Find Similar Products
Basic Info.
- Model NO.
- MP551
- pH Measuring Range
- ( -2.000 ~ 19.999)pH
- Size
- 160 * 190* 70mm
- Color
- No
- Material
- No
- Communication Interface
- RS 232
- pH Resolution Ratio
- 0.1/0.01/0.001 pH
- Source
- DC9V/300mA
- Customized Support
- OEM
- Power
- No
- Mv Resolution Ratio
- 0.1mv
- Quality and Safety Certification
- ISO 9001:2015, CE, and CMC
- Transport Package
- Box
- Specification
- 160 * 190* 70mm
- Trademark
- Haiker
- Origin
- Shanghai, China
- Production Capacity
- 300000
Product Description
MP551 PH/mV Dionconcentration Iconductivity/Dlissoved oxygen meter
1.Meet the GLP requirements of international specifications, with intelligent functions such as automatic calibration, automatic temperature compensation, data storage, R S 232 output, clock display, function setting and self-diagnosis information.
2.There are three different measurement modes: stable display mode; timing measurement mode and continuous measurement mode.
3.Automatic identification of 13 pH standard buffer solutions, there are four series of standard buffer solutions can be selected: European and American series, NIST series, China series and custom solution.
4.Standard with Swiss high-end LabSen, glass rechargeable composite electrode, high precision measurement, long life reference, thick film and low impedance glass film. High purity water pH measurement mode and ammonia added pure water pH measurement mode can be set to meet the use requirements of electric power,petrochemical and other industries.
5.There is EH redox potential measurement mode that directly showing the ORP value relative to the standard hydrogen electrode potential.
6.Automatic identification of 8 kinds of conductivity standard solutions, there are two series of standard solutions can be selected: European and American series and China series.
7.Using advanced conductivity measurement technology, the use of constant K =1 conductive electrode only a little calibration, can meet the measurement accuracy requirements of 0.5 μ S / cm ~ 200 mS / cm.
2.There are three different measurement modes: stable display mode; timing measurement mode and continuous measurement mode.
3.Automatic identification of 13 pH standard buffer solutions, there are four series of standard buffer solutions can be selected: European and American series, NIST series, China series and custom solution.
4.Standard with Swiss high-end LabSen, glass rechargeable composite electrode, high precision measurement, long life reference, thick film and low impedance glass film. High purity water pH measurement mode and ammonia added pure water pH measurement mode can be set to meet the use requirements of electric power,petrochemical and other industries.
5.There is EH redox potential measurement mode that directly showing the ORP value relative to the standard hydrogen electrode potential.
6.Automatic identification of 8 kinds of conductivity standard solutions, there are two series of standard solutions can be selected: European and American series and China series.
7.Using advanced conductivity measurement technology, the use of constant K =1 conductive electrode only a little calibration, can meet the measurement accuracy requirements of 0.5 μ S / cm ~ 200 mS / cm.
8.Switch the conductivity, TDS, salinity and resistivity. TDS and salinity are calculated using polynomials to ensure the conversion accuracy of the full range.
9.The conductivity measurement mode has the function of high-purity water nonlinear temperature compensation.
10.The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation.
11.The patented polar spectral dissolved oxygen electrode can measure the temperature, salinity and dissolved oxygen at the same time. With a special dissolved oxygen electrode calibration set, the electrode polarization only takes 3~5 min.
12.The instrument stores 10 commonly used ion modes (Na +, F-, Cl-, Br-, I-, Cu 2 +, Ca 2 +, K +, NH4 +, NO3-), and other ions can also be set by themselves.
10.The dissolved oxygen measurement mode has the functions of automatic temperature compensation, automatic salinity compensation and automatic air pressure compensation.
11.The patented polar spectral dissolved oxygen electrode can measure the temperature, salinity and dissolved oxygen at the same time. With a special dissolved oxygen electrode calibration set, the electrode polarization only takes 3~5 min.
12.The instrument stores 10 commonly used ion modes (Na +, F-, Cl-, Br-, I-, Cu 2 +, Ca 2 +, K +, NH4 +, NO3-), and other ions can also be set by themselves.
13.Four ion concentration units can be switched: pX, mol/L, mg/L and ppm.
14.Standard intelligent agitator, support speed storage, convenient to maintain the measurement repeatability.
15.Meet the I P 54 dust and splash prevention grade, the instrument socket is equipped with silicone cap seal protection.
15.Meet the I P 54 dust and splash prevention grade, the instrument socket is equipped with silicone cap seal protection.
|
p H |
measuring range
|
( -2.000 ~ 19.999)pH
|
|
resolution ratio
|
0.1/0.01/0.001 pH
|
|
|
accuracy
|
Electrometer: ± 0.002 pH, matching: ± 0.01 pH
|
|
|
stability
|
±0.002 pH/3h
|
|
|
temperature compensation range
|
(0 ~ 100) ºC (automatic or manual)
|
|
|
m V |
Measuring range (mV / ORP / EH)
|
-1999.9mV ~ 0 ~ 1999.9m V
|
|
resolution ratio
|
0.1mV
|
|
|
accuracy
|
±0.03% FS
|
|
|
ionic concentratio n |
measuring range
|
0.00 ~ 14.00 p X
|
|
Display unit
|
p X ,mol /L ,mg /L ,ppm
|
|
|
accuracy
|
Electrometer: ± 0.5% read value (one price), ± 1.0% read value (bivalent)
|
|
|
temperature compensation range
|
0 ~ 60ºC (automatic or manual)
|
|
|
Preset the ion mode
|
Na + ,F- ,Cl- ,Br- ,I - ,Cu2+ ,Ca2+ ,K+ ,NH4+ ,NO3
|
|
|
conductivity |
measuring range |
Conductivity: (0.00 ~20.00) μ S / cm
(20.0 ~200.0) μ S /cm (200 ~2000) μ S /cm (2 .00 ~20.00) mS /cm
(20 .0 ~200.0) mS / cm (200 ~2000) mS / cm ( K = 10) Resistivity: (0 ~ 100) M Ω · cm
TDS : (0 ~ 100)g /L Salinity: (0 ~ 100) ppt |
|
resolution ratio
|
0.01/0.1/1μ S /cm 0.01/0.1/1 mS /cm
|
|
|
definition
|
Electrometer: ± 0.5% FS, matching: ± 0.80%FS
|
|
|
temperature compensation range
|
(0 ~ 50) ºC (automatic)
|
|
|
The electrode constant
|
0.1 / 0.5 / 1 / 5 / 10 / 50 / 100 cm-1
|
|
|
reference temperature
|
25ºC, 20ºC, and 18ºC
|
|
|
dissolved oxygen |
measuring range
|
(0 ~ 20.00) mg /L (ppm ) (0 ~ 200.0)%
|
|
resolution ratio
|
0.1/0.01 mg /L (ppm ) 1/0.1 %
|
|
|
accuracy
|
Electrometer: ± 0.10 mg/L, matching: ± 0.40 mg / L
|
|
|
response time
|
30s (25ºC, 90% response)
|
|
|
aftercurrent
|
≤ 0.1 mg/L
|
|
|
temperature compensation range
|
(0 ~ 45) ºC (automatic)
|
|
|
Salinity compensation range
|
(0 ~ 45) ppt (automatic)
|
|
|
Air-pressure compensation range
|
(80 ~ 105) kPa (automatic)
|
|
|
automatic calibration
|
Air saturated with water; water saturated with air
|
|
|
The type of electrode
|
Polar spectrum
|
|
|
temperature |
measuring range
|
-10ºC ~ 110ºC
|
|
resolution ratio
|
0.1ºC
|
|
|
accuracy
|
5~ 60ºC Range: ± 0.4ºC Other range: ± 0.8ºC
|
|
|
Other technical parameters |
data storage
|
300 Groups
|
|
Store content
|
Measurement value number, measurement value, temperature value, ATC or MTC status, measurement date, measurement time
|
|
|
source
|
DC9V/300mA
|
|
|
communication interface
|
RS 232
|
|
|
Size and weight
|
160 × 190 × 70mm/880g
|
|
|
Quality and safety certification
|
ISO 9001:2015, CE, and CMC
|
|
|
going |
ambient temperature
|
5 ~ 35ºC (Grade 0.01) 15-30ºC (Grade 0.001)
|
|
ambient humidity
|
≤ 75%
|
|
|
IP grade
|
IP 54 Dustproof and splash-proof
|
|
1. Type MP 551 p H/mV / ion concentration / conductivity / dissolved oxygen measurement meter
|
One
|
|
Type 2. 602 universal direction electrode frame
|
One
|
|
Type 3. 901 smart mixer
|
One
|
|
4. 201T-M plastic shell pH / ATC triple composite electrode
|
1 Branch
|
|
5. LabSen 211 glass pH composite electrode
|
1 Branch
|
|
The 6. MP500 temperature electrode
|
1 Branch
|
|
7. 2401-M conductive electrode
|
1 Branch
|
|
8. DO 500, and the dissolved oxygen electrode
|
1 Branch
|
|
9.6 Type 213 double salt bridge reference electrode
|
1 Branch
|
|
10. pH corrected buffer solution (pH 4.00, pH 6.86, pH 9.18 / 50ml)
|
Each 1 bottle
|
|
11.1408 μ S / cm Conductivity correction solution (50ml)
|
1 Bottle
|
|
12.9V Power adapter (instrument use)
|
One
|
|
13.6V power adapter (provided with mixer)
|
One
|
|
14. DO 503 diaphragm cap (dissolved oxygen electrode)
|
Three
|
|
15. DO 502 solution in dissolved oxygen electrode (30ml)
|
1 Bottle
|
|
16. Cathodic polishing paper
|
2 Xiao Zhang
|
|
17 B628 stirred the beads
|
Three grains
|
|
18. RS232 Communication cable
|
One root
|
|
19. MP551 communication software CD
|
One
|
|
20., The instruction manual
|
One
|
|
21. Brief operation guide
|
One
|
ABOUT US
Q1What is your minimum order quantity? A1The minimum order quantity is very low, and the minimum order is one set. For customized projects, it depends on different requirements. Q2Do you offer guarantee for the products? A2Yes, we offer 1-2 years warranty to our products. Q3What is the delivrey time after an drder placed? A3Our standard delivery is 3-5days when we have stock.We will let you know the lead time according to your oder quantity in time. Q4What is the warranty? A4The free warranty is one year from the day of Commissioning qualified. Q5Can you tell me your main customers? A5Sorry we could not tell you except customer's permission. At the same time,your information also will be protected. Q6How can i get the after-service? A6We will be responsible for our products in the valid time.
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Environmental Monitoring Instruments
- Water Quality Analyzer
- MP551pH Meter Mv Ion Concentration Conductivity Dissolved Oxygen Meter Multi Parameter Water Quality Analysis
Related Categories
Hot Searches
More